Seismic Zone Criteria in Data Center
When designing and operating a data center in a seismically active zone, specific criteria must be adhered to in order to ensure the safety and integrity of the facility and its operations. Here are the detailed criteria and considerations for data centers in seismic zones:
1. Site Selection and Assessment
Seismic Risk Assessment: Conduct a thorough geological survey to assess the seismic risk of the site. This includes analyzing historical earthquake data, fault lines, soil conditions, and liquefaction potential.
Building Codes and Standards: Adhere to local and international building codes and standards for seismic design, such as the International Building Code (IBC), ASCE 7 (Minimum Design Loads for Buildings and Other Structures), and local seismic regulations.
2. Structural Design
Seismic-Resistant Structures: Design the building structure to withstand seismic forces. This includes the use of reinforced concrete, steel framing, and shear walls to provide additional strength and flexibility.
Base Isolation Systems: Implement base isolation techniques to decouple the building from ground motion, reducing the transmission of seismic forces to the structure.
Damping Systems: Utilize energy dissipation devices, such as tuned mass dampers or viscous dampers, to absorb and dissipate seismic energy.
3. Non-Structural Elements
Raised Floors: Design and secure raised floors to prevent collapse during an earthquake. This includes bracing and anchoring floor tiles and support structures.
Equipment Anchoring: Ensure all equipment, such as servers, racks, and cabinets, are securely anchored to prevent tipping or sliding. Use seismic-rated mounts and brackets.
Cable Management: Use flexible and properly secured cable management systems to prevent damage to power and data cables during seismic events.
4. Infrastructure and Utilities
Power Systems: Ensure Uninterruptible Power Supplies (UPS), backup generators, and batteries are seismically anchored and housed in reinforced enclosures.
Cooling Systems: Secure HVAC units, chillers, and cooling towers to prevent movement and damage. Use flexible connections for piping and ductwork to accommodate movement.
Fire Suppression Systems: Install flexible piping for fire suppression systems, such as sprinklers and gas-based systems, to prevent leaks and ensure functionality during and after an earthquake.
5. Seismic Retrofitting
Existing Facilities: For data centers located in seismic zones but not originally designed for seismic resistance, conduct a seismic vulnerability assessment and implement retrofitting measures. This may include reinforcing structural elements, adding shear walls, and upgrading non-structural components.
Detailed Examples of Implementation
1. Base Isolation Example: The Transbay Transit Center in San Francisco employs base isolation to protect the structure from seismic forces. Data centers in high-risk areas can use similar technology to enhance stability.
2. Seismic-Resistant Racks: Use server racks designed with reinforced frames and locking mechanisms that can withstand shaking. Products like the APC NetShelter SX Seismic offer these features.
3. Flexible Couplings: Install flexible couplings in plumbing and electrical conduit systems to absorb movement and prevent ruptures or disconnections during an earthquake.
Designing and operating a data center in a seismic zone requires meticulous planning and adherence to specific criteria to ensure the safety and reliability of the facility. By integrating structural reinforcements, securing non-structural components, preparing operational protocols, and staying compliant with relevant standards, data centers can effectively mitigate the risks associated with seismic activity and ensure continuous operation even in the face of natural disasters.